Introduction: Abnormalities in regional left ventricular (LV) function in severe aortic stenosis (AS) have yet to be appropriately characterized. Often patients with severe aortic stenosis have subclinical left ventricular systolic dysfunction despite having preserved ejection fraction and fractional shortening on conventional echocardiography. In these patients, the occult, systolic abnormalities are underestimated and have been shown to contribute to symptoms, morbidity and mortality. Two-dimensional strain ( ) and strain rate imaging (SRI), are new ultrasound (US) indices for quantifying regional wall deformation. Mitral annular velocities derived from tissue Doppler imaging (TDI) have already been shown to complement established parameters in evaluating early systolic and diastolic performance post aortic valve replacement. However, the widespread use of this methodology remains limited. This finding can likely be attributed to the fact that Doppler-derived velocity and deformation data are one-dimensional, that is, only the velocity and deformation component along an image line can be assessed, resulting in an angle –dependency of the measurements. Tissue velocity 2D strain and strain rate imaging with speckle tracking is a novel method of assessing regional as well as global "contractility". This method overcomes many limitations inherent in assessing myocardial functioning with current methodology, mainly it is reproducible, objective, and is independent of myocardial translation, tethering and furthermore as speckle tracking is derived from B mode images is independent of Doppler angle. The applicability of this technology to patients with aortic valve stenosis and subclinical systolic dysfunction and its clinical significance has not been evaluated.
Objectives: The general aims of this study were to compare regional displacement, tissue velocity, strain ( ) and strain rate (SR) in severe AS pre and post operatively. Specifically, we sought, to investigate whether Speckle derived tissue velocity and SR could be useful to detect subtle left ventricular (LV) dysfunction in patients with severe aortic stenosis but preserved ejection fraction, and if they can reliably detect improvements in regional myocardial function after aortic valve replacement (AVR). We hypothesize that those patients with severe AS will have significantly reduced peak systolic and peak early diastolic displacement, strain and strain rates at baseline compared with normal controls, despite having normal ejection fraction and fractional shortening as assessed by conventional echocardiography. In addition, we hypothesise that post AVR; deformation patterns will show an early (4-16 weeks) improvement in the myocardial strain and strain rate preceding any changes in LV systolic and diastolic dysfunction assessed by conventional echocardiography.
Methodology: Our study prospectively analyzed 24 consecutive patients in total. Ten control subjects (5 women, 5 men, and mean age 29.6 ± 5.7.3 years) provided normal values of tissue displacement, velocity strain and strain rate. We then, prospectively analyzed 10 patients with severe aortic stenosis and preserved EF and FS, with speckle imaging derived tissue displacement, velocity, strain and strain rate imaging pre –operatively (mean age 71.14± 16.15) and four of these patient post operatively (mean age 79.25 ± 1.7) for aortic valve replacement. This was done as part of routine pre-operative and post-operative transthoracic echocardiography using standard views, with the exception that all studies would need to be done on the GE Vivid 7 digital ultrasound system. Speckle derived imaging data is derived from standard B mode (Grey scale images), with a frame rate of between 40- 90 frames/s. Post-operative TTE’s were performed at 4-20 weeks after discharge. Baseline characteristics were taken from the standard pre-operative baseline study including basic 2 D valve area, EF, wall thickness and geometry, and Doppler flow data. Exclusion criteria: Patients with prior cardiac surgery including CABG or other valve replacement, more than moderate mitral valve or aortic regurgitation and chronic kidney disease (Cr >180), emergent aortic valve replacement, or endocarditis. Informed consent was obtained on all patients, and they were only included if they consent. No surgery was delayed for purpose of the study if the proper hardware/GE VIVID system was not available.
Conclusion: Our results indicate that a reduction of displacement, tissue velocity, strain, and strain rate may be a sensitive marker of subtle, subclinical, subendocardial myocardial dysfunction. More over, these parameters seemed to be superior to conventional echocardiography in detecting subtle improvements in myocardial function after AVR before LV dimensions and LV function showed improvement.

CONSULTA INTEGRALMENTE QUESTA TESI

La consultazione è esclusivamente in formato digitale .PDF

Acquista
Mostra/Nascondi contenuto.
Charles Mugera 00395247 MSc Medical Ultrasound 2 Two dimensional analysis of left ventricular myocardial regional and global contractility using speckle tracking pre and post aortic valve replacement for aortic stenosis. _____________________________________________________________________ _ Dr Charles M Mugera Echocardiography department Hammersmith Hospital, London MSc medical ultrasound Clinical sciences centre

CONSULTA INTEGRALMENTE QUESTA TESI

La consultazione è esclusivamente in formato digitale .PDF

Acquista
Il miglior software antiplagio

L'unico servizio antiplagio competitivo nel prezzo che garantisce l'aiuto della nostra redazione nel controllo dei risultati.
Analisi sicura e anonima al 100%!
Ottieni un Certificato Antiplagio dopo la valutazione.

Informazioni tesi

  Autore: Charles Mugera
  Tipo: International thesis/dissertation
  Anno: -
  Università: Imperial College of Science, Technology and Medicine
  Corso: Clinical sciences centre, Hammersmith Hospital, London
  Relatore: Petros  Nihoyannopoulos
  Lingua:
  Num. pagine: 89

FAQ

Per consultare la tesi è necessario essere registrati e acquistare la consultazione integrale del file, al costo di 29,89€.
Il pagamento può essere effettuato tramite carta di credito/carta prepagata, PayPal, bonifico bancario.
Confermato il pagamento si potrà consultare i file esclusivamente in formato .PDF accedendo alla propria Home Personale. Si potrà quindi procedere a salvare o stampare il file.
Maggiori informazioni
Ingiustamente snobbata durante le ricerche bibliografiche, una tesi di laurea si rivela decisamente utile:
  • perché affronta un singolo argomento in modo sintetico e specifico come altri testi non fanno;
  • perché è un lavoro originale che si basa su una ricerca bibliografica accurata;
  • perché, a differenza di altri materiali che puoi reperire online, una tesi di laurea è stata verificata da un docente universitario e dalla commissione in sede d'esame. La nostra redazione inoltre controlla prima della pubblicazione la completezza dei materiali e, dal 2009, anche l'originalità della tesi attraverso il software antiplagio Compilatio.net.
  • L'utilizzo della consultazione integrale della tesi da parte dell'Utente che ne acquista il diritto è da considerarsi esclusivamente privato.
  • Nel caso in cui l’utente che consulta la tesi volesse citarne alcune parti, dovrà inserire correttamente la fonte, come si cita un qualsiasi altro testo di riferimento bibliografico.
  • L'Utente è l'unico ed esclusivo responsabile del materiale di cui acquista il diritto alla consultazione. Si impegna a non divulgare a mezzo stampa, editoria in genere, televisione, radio, Internet e/o qualsiasi altro mezzo divulgativo esistente o che venisse inventato, il contenuto della tesi che consulta o stralci della medesima. Verrà perseguito legalmente nel caso di riproduzione totale e/o parziale su qualsiasi mezzo e/o su qualsiasi supporto, nel caso di divulgazione nonché nel caso di ricavo economico derivante dallo sfruttamento del diritto acquisito.
L'obiettivo di Tesionline è quello di rendere accessibile a una platea il più possibile vasta il patrimonio di cultura e conoscenza contenuto nelle tesi.
Per raggiungerlo, è fondamentale superare la barriera rappresentata dalla lingua. Ecco perché cerchiamo persone disponibili ad effettuare la traduzione delle tesi pubblicate nel nostro sito.
Per tradurre questa tesi clicca qui »
Scopri come funziona »

DUBBI? Contattaci

Contatta la redazione a
[email protected]

Ci trovi su Skype (redazione_tesi)
dalle 9:00 alle 13:00

Oppure vieni a trovarci su

Parole chiave

aortic stenosis
aortic valve replacement
echocardiography
speckle tracking imaging
strain
strain rate
tissue doppler imaging

Tesi correlate


Non hai trovato quello che cercavi?


Abbiamo più di 45.000 Tesi di Laurea: cerca nel nostro database

Oppure consulta la sezione dedicata ad appunti universitari selezionati e pubblicati dalla nostra redazione

Ottimizza la tua ricerca:

  • individua con precisione le parole chiave specifiche della tua ricerca
  • elimina i termini non significativi (aggettivi, articoli, avverbi...)
  • se non hai risultati amplia la ricerca con termini via via più generici (ad esempio da "anziano oncologico" a "paziente oncologico")
  • utilizza la ricerca avanzata
  • utilizza gli operatori booleani (and, or, "")

Idee per la tesi?

Scopri le migliori tesi scelte da noi sugli argomenti recenti


Come si scrive una tesi di laurea?


A quale cattedra chiedere la tesi? Quale sarà il docente più disponibile? Quale l'argomento più interessante per me? ...e quale quello più interessante per il mondo del lavoro?

Scarica gratuitamente la nostra guida "Come si scrive una tesi di laurea" e iscriviti alla newsletter per ricevere consigli e materiale utile.


La tesi l'ho già scritta,
ora cosa ne faccio?


La tua tesi ti ha aiutato ad ottenere quel sudato titolo di studio, ma può darti molto di più: ti differenzia dai tuoi colleghi universitari, mostra i tuoi interessi ed è un lavoro di ricerca unico, che può essere utile anche ad altri.

Il nostro consiglio è di non sprecare tutto questo lavoro:

È ora di pubblicare la tesi